For high-rise and mid-rise residential communities: egress, shafts, e-bike parking and charging, common-area fire systems, facades, and control-room patrols. Follow design documents, maintenance contracts, local rules, and authority requirements.
0 / 39 completed Clear checks
Inside your unit
✓ No electric vehicles/batteries parked or charged indoors; no illegal wiring or overloaded strips ✓ No high-power heaters in children's rooms; unplug when done ✓ No bottled LPG indoors in high-rise buildings (规定 12.0.4) GB 55037-2022 ✓ Do not leave cooking or high-power appliances unattended ✓ Kitchen gas appliances and hoses leak-free; no combustibles near stove; hood ducts cleaned ✓ Balconies and window ledges free of boxes, clutter, and other combustibles ✓ Escape windows not fitted with bars that cannot be opened from inside ✓ Before leaving—three clears (balcony, kitchen, egress path) and three offs (fire, gas, power) ✓ Suggested home kit: fire blanket, extinguisher, standalone smoke alarm, high-temp door-seal tape, torch, escape hood, rope/descender (as appropriate) Facade
✓ Facade signs and cladding: no combustibles; above 50 m, noncombustible and easy to break open ✓ Windows, especially rescue windows, have no bars or signs that block escape or firefighting Corridor & stair public areas
✓ Corridors, stairs, and exits clear—no shoes, clutter, e-bikes, or combustibles ✓ Pressurized stair doors closed; vestibules clear; supply fans/outlets OK ✓ Floor fire doors/curtains: closers, coordinators, labels OK—no wedging ✓ Chutes/shafts: firestops intact, no storage, normally closed doors shut ✓ Common areas over 100 m²: one 1A extinguisher, plus one more per extra 100 m² ✓ Evacuation diagram posted; valves lead-sealed or locked E-bike parking and charging
✓ Central charging has auto cut-off when full, plus extinguishers ✓ No illegal cable charging (including cables run out of windows or balconies) ✓ No e-bikes in lobbies, stairs, exits, vestibules, or lift halls ✓ Central e-bike storage is separate, or fire-separated when inside the building ✓ No e-bikes or batteries in elevator cars, lobbies, stairs, or fire lanes (Shanghai) ✓ Charging area extinguishers OK, no combustibles; property patrols and records for illegal parking/charging Property-managed fire systems
✓ Fire lanes and aerial pads have no parking, bollards, or overhead signs ✓ No vehicles within 5 m each side of outdoor hydrants and fire-pump inlets ✓ This year: resident training and an evacuation drill, plus a full-scale drill, with records ✓ Common-area hydrants/extinguishers complete, labeled, in date ✓ Alarm/voice evacuation: no chronic faults; strobes and manual stations OK ✓ Sprinklers/pumps: end-test logs on file; valves open; heads unobstructed ✓ Smoke fans, exhaust openings, and openable windows interlock OK ✓ Garage/plant floors labeled; gas detection (if any) normal ✓ Control room 24-hour duty with ≥2 certified staff; drawings and test reports on file ✓ Daily patrols, maintenance contracts, fit-out/hot-work permits, closed-loop fixes Escape essentials (memorize)
✓ Know escape routes—stay calm. Fire above: close door and go down; fire below with smoky stairs: return inside, close door, await rescue ✓ Use an extinguisher on small fires; leave immediately if fire or smoke spreads ✓ Use stairs, not elevators; stay low in smoke; cover nose/mouth with a damp cloth ✓ Close doors; if trapped, go to refuge floor/room or signal from a window ✓ Call 119 with exact address, fire floor, trapped count; meet crews in a safe area ✓ Control room 24h with ≥2 certified staff; drawings and test reports on file For community training and self-checks only—not an inspection, test, or legal opinion. Use qualified firms and official guidance for major hazards and system testing.